<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gemu Valves &#187; admin</title>
	<atom:link href="http://gemuvalvesonline.com/author/admin/feed/" rel="self" type="application/rss+xml" />
	<link>http://gemuvalvesonline.com</link>
	<description></description>
	<lastBuildDate>Sat, 13 Sep 2014 18:12:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.42</generator>
	<item>
		<title>Hello world!</title>
		<link>http://gemuvalvesonline.com/hello-world/</link>
		<comments>http://gemuvalvesonline.com/hello-world/#comments</comments>
		<pubDate>Sat, 06 Sep 2014 20:35:20 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=1</guid>
		<description><![CDATA[Welcome to WordPress. This is your first post. Edit or delete it, then start blogging!]]></description>
				<content:encoded><![CDATA[<p>Welcome to WordPress. This is your first post. Edit or delete it, then start blogging!</p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/hello-world/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Manual Override, Flange, Screwed Union</title>
		<link>http://gemuvalvesonline.com/manual-override-flange-screwed-union/</link>
		<comments>http://gemuvalvesonline.com/manual-override-flange-screwed-union/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:49:12 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=68</guid>
		<description><![CDATA[MANUAL OVERRIDE &#160;1002 For valve types: 312, 314, 512, 514, 687, 690, 695 &#160; &#160; &#160; &#160; &#160; Flange 1034 For valve types: 677, 690, 693 &#160; &#160; Screwed Union 1035 For valve types: 667, 677, 690, 693]]></description>
				<content:encoded><![CDATA[<p align="left">
<b><span style="text-transform: uppercase"><span style="font-size: 10pt; font-family: Arial; color: #ff0000">MANUAL OVERRIDE</span></span></b>
</p>
<table border="0" cellpadding="0" cellspacing="0" width="100%">
<tbody>
<tr>
<td valign="top" width="50%"><span style="font-size: 10pt; font-family: Arial">&nbsp;<b>1002</b></span></p>
<p>
			<span style="font-size: 10pt; font-family: Arial">For valve types:<br />
			312, 314, 512, 514, 687, 690, 695</span>
			</p>
<p>
			&nbsp;
			</p>
<p>
			&nbsp;
			</p>
<p>
			&nbsp;
			</p>
</td>
</tr>
<tr>
<td width="50%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
</tr>
<tr>
<td width="50%"><b><span style="font-family: Arial"><span style="text-transform: uppercase"><span style="font-size: 10pt; color: #ff0000">Flange</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT; color: #800080"><br />
			</span></span></b></td>
</tr>
<tr>
<td width="50%"><span style="font-size: 10pt; font-family: Arial"><b>1034</b></span></p>
<p>
			<span style="font-size: 10pt; font-family: Arial">For valve types:<br />
			677, 690, 693</span>
			</p>
</td>
</tr>
<tr>
<td valign="top" width="50%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
</tr>
<tr>
<td valign="top" width="50%"><b><span style="font-family: Arial"><span style="text-transform: uppercase"><span style="font-size: 10pt; color: #ff0000">Screwed Union</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT; color: #800080"><br />
			</span></span></b></td>
</tr>
<tr>
<td valign="top" width="50%"><b><span style="font-size: 10pt; font-family: Arial">1035</span></b></p>
<p>
			<span style="font-size: 10pt; font-family: Arial">For valve types:<br />
			667, 677, 690, 693</span>
			</p>
</td>
</tr>
</tbody>
</table>
<p><span id="more-68"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/manual-override-flange-screwed-union/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Accessories for Flowmeters</title>
		<link>http://gemuvalvesonline.com/accessories-for-flowmeters/</link>
		<comments>http://gemuvalvesonline.com/accessories-for-flowmeters/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:47:50 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=67</guid>
		<description><![CDATA[&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160; 1251 / 1252 For flowmeter types: 815, 817, 835, 865 DN25, 867 DN 25 &#160; &#160; &#160; &#160; Limit Switch &#160; &#160;1256 / 1257 For flowmeter types: 865 DN10, 15, 20 867 DN 10, 15, 20 Limit Switch &#160; 1270 / 1273 For flowmeter types: 815, 817, 835, 865, 867 1270/1271, 0-10k W 1272/1273, [&#8230;]]]></description>
				<content:encoded><![CDATA[<table border="0" cellpadding="0" cellspacing="0" width="100%">
<tbody>
<tr>
<td valign="top" width="50%">
<p align="left">
			<span style="font-size: 10pt; font-family: Arial">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a name="1251 / 1252" title="1251 / 1252"></a><b>1251 / 1252</b></span>
			</p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial">For flowmeter types:<br />
			815, 817, 835, 865 DN25, 867 DN 25</span>
			</p>
<p align="left">
			&nbsp;
			</p>
<p align="left">
			&nbsp;
			</p>
<p align="left">
			&nbsp;
			</p>
<p align="left">
			&nbsp;
			</p>
<p align="left">
			<i><b><span style="font-size: 10pt; font-family: Arial">Limit Switch</span></b></i>
			</p>
<hr align="center" />
			</td>
</tr>
<tr>
<td width="50%">&nbsp;</td>
</tr>
<tr>
<td width="50%"><span style="font-size: 10pt; font-family: Arial">&nbsp;<a name="1256 / 1257" title="1256 / 1257"></a><b>1256 / 1257</b></span></p>
<p>
			<span style="font-size: 10pt; font-family: Arial">For flowmeter types:<br />
			865 DN10, 15, 20<br />
			867 DN 10, 15, 20</span>
			</p>
<p>
			<i><b><span style="font-size: 10pt; font-family: Arial">Limit Switch</span></b></i>
			</p>
<hr align="center" />
			</td>
</tr>
<tr>
<td width="50%">&nbsp;</td>
</tr>
<tr>
<td valign="top" width="50%"><span style="font-size: 10pt; font-family: Arial"><b>1270 / 1273</b></span></p>
<p>
			<span style="font-size: 10pt; font-family: Arial">For flowmeter types:<br />
			815, 817, 835, 865, 867</p>
<p>			1270/1271, 0-10k W <br />
			1272/1273, 4-20 mA</span>
			</p>
<p>
			&nbsp;
			</p>
<p>
			&nbsp;
			</p>
<p>
			&nbsp;
			</p>
<p>
			<i><b><span style="font-size: 10pt; font-family: Arial">Continuous sensor</span></b></i>
			</p>
</td>
</tr>
</tbody>
</table>
<p><span id="more-67"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/accessories-for-flowmeters/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Positioners</title>
		<link>http://gemuvalvesonline.com/positioners/</link>
		<comments>http://gemuvalvesonline.com/positioners/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:47:00 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=66</guid>
		<description><![CDATA[1434 &#160; &#160;1434 Positioner PDF &#160; 1435 1435 Positioner PDF 1436 1436 Positioner PDF 1434-1436 Overview PDF]]></description>
				<content:encoded><![CDATA[<table border="0" width="100%">
<tbody>
<tr>
<td width="50%"><strong><span style="font-size: 10pt; color: #ff0000; font-family: Arial"></p>
<p align="left">
			<strong><span style="font-size: 10pt; color: #ff0000; font-family: Arial">1434</span></strong>
			</p>
<p align="left">
			&nbsp;
			</p>
<p align="left">
			<br />
			&nbsp;<a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1434_positioner.pdf" title="1434 Positioner PDF" class="jce_file">1434 Positioner PDF</a>
			</p>
<p>			</span></strong></p>
<hr align="center" />
			</td>
</tr>
<tr>
<td width="50%">
<p>
			&nbsp;
			</p>
</td>
</tr>
<tr>
<td width="50%" vAlign="top">
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"><strong>1435</strong></span></span>
			</p>
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
<p>			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"><a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1435%20Positioner.pdf" title="1435 Positioner PDF" class="jce_file"><strong>1435 Positioner PDF</strong></a></p>
<hr align="center" />
<p>
			<span style="font-family: Verdana"></span>
			</p>
<p>			</span></span></td>
</tr>
</tbody>
</table>
<table border="0" width="574" style="width: 574px; height: 200px">
<tbody>
<tr>
<td width="50%"><span style="font-size: 10pt; color: #ff0000; font-family: Arial"></p>
<p align="left">
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><strong>1436</strong></span>
			</p>
<p>			</span><a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1436_positioner.pdf" title="1436 Positioner PDF" class="jce_file"><strong>1436 Positioner PDF</strong></a></p>
<hr align="center" />
			</td>
</tr>
<tr>
<td width="50%">
<p>
			<a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1434-1436_Overview.pdf" title="1434-1436 Overview PDF" class="jce_file"><strong>1434-1436 Overview PDF</strong></a>
			</p>
</td>
</tr>
<tr>
<td width="50%" vAlign="top">
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
</td>
</tr>
</tbody>
</table>
<p><span id="more-66"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/positioners/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Mounting Brackets &amp; Plates</title>
		<link>http://gemuvalvesonline.com/mounting-brackets-plates/</link>
		<comments>http://gemuvalvesonline.com/mounting-brackets-plates/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:46:14 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=65</guid>
		<description><![CDATA[1450 For valve types: 312, 314, 512, 514, 520, 554, 620, 687, 690, 695 &#160; &#160; Mounting bracket complying with NAMUR 1460/1005 For valve types: 520, 620 With handwheel &#160; Mounting bracket complying with NAMUR &#160; &#160; &#160; 1040 For valve types: 105, 205, 225 &#160; Complete with fixing screws Mounting Plate 1041 For valve [&#8230;]]]></description>
				<content:encoded><![CDATA[<table border="0" width="100%">
<tbody>
<tr>
<td width="54%"><span style="font-family: Arial"><b><span style="font-size: 10pt; color: #ff0000">1450</span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			For valve types:<br />
			312, 314, 512, 514, 520, 554, 620, 687, 690, 695</span></span></p>
<p>
			&nbsp;
			</p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-family: Arial"><i><b><span style="font-size: 10pt">Mounting bracket</span> </b></i><span style="font-size: 10pt"><br />
			complying with NAMUR</span></span>
			</p>
</td>
<td valign="top" width="46%"><span style="font-size: 10pt; font-family: Arial"><span style="color: #ff0000"><b>1460/1005</b></span></p>
<p>			For valve types:<br />
			520, 620</p>
<p>			With handwheel</span></p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-family: Arial"><i><b><span style="font-size: 10pt">Mounting bracket</span> </b></i><span style="font-size: 10pt"><br />
			complying with NAMUR</span></span>
			</p>
</td>
</tr>
<tr>
<td width="54%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td width="46%">&nbsp;</td>
</tr>
<tr>
<td valign="top" width="54%"><span style="font-family: Arial"><b><span style="font-size: 10pt; color: #ff0000">1040</span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			</span></span></p>
<p>
			<span style="font-size: 10pt; font-family: Arial">For valve types: 105, 205, 225</span>
			</p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial"><br />
			Complete with fixing screws<br />
			<i><b>Mounting Plate</b></i></span>
			</p>
</td>
<td valign="top" width="46%">
<p align="left">
			<b><span style="font-size: 10pt; font-family: Arial; color: #ff0000">1041</span></b>
			</p>
<p align="left">
			<span style="font-family: Arial"><span style="font-size: 10pt; font-family: AvantGarde Bk BT">For valve types:<br />
			600, 610, 613, 617,<br />
			667, 690, 693</span></span>
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial"><br />
			</span>
			</p>
<p>
			<b><span style="font-family: Arial"><i><span style="font-size: 10pt">Mounting and compensating plate</span></i><span style="font-size: 10pt; font-family: AvantGarde Bk BT">s</span></span></b>
			</p>
</td>
</tr>
<tr>
<td width="54%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td width="46%">&nbsp;</td>
</tr>
<tr>
<td width="54%">
<p align="left">
			<b><span style="font-size: 10pt; font-family: Arial; color: #ff0000">1050</span></b>
			</p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial">For types 320, 322.<br />
			</span>
			</p>
<p align="left">
			&nbsp;
			</p>
<p align="left">
			<i><b><span style="font-size: 10pt; font-family: Arial">Mounting Plate</span></b></i>
			</p>
</td>
</tr>
</tbody>
</table>
<p><span id="more-65"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/mounting-brackets-plates/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Stroke Limiters</title>
		<link>http://gemuvalvesonline.com/stroke-limiters/</link>
		<comments>http://gemuvalvesonline.com/stroke-limiters/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:45:24 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=64</guid>
		<description><![CDATA[1100/1101/1103/1104 Control function 1 Stroke Limiter 1110/1111 Control function 2 Stroke Limiter &#160; &#160; &#160; 1114 With optical position indicator and emergency manual operation facility Stroke Limiter 1151/1153/1154 With optical position indicator Control function 1 Stroke Limiter &#160; &#160; &#160; 1161/1165 &#160; With optical position indicator Control function 2 Stroke Limiter 1301 For the type [&#8230;]]]></description>
				<content:encoded><![CDATA[<table border="0" cellpadding="0" cellspacing="0" width="76%">
<tbody>
<tr>
<td valign="top" width="40%">
<p align="left">
			<b><span style="font-size: 10pt; font-family: Arial">1100/1101/1103/1104</span></b>
			</p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial"><br />
			 </span>
			</p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial">Control function 1<br />
			<i><b>Stroke Limiter</b></i></span>
			</p>
</td>
<td valign="top" width="60%"><b><span style="font-size: 10pt; font-family: Arial">1110/1111</span></b></p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial"><br />
			</span>
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial">Control function 2<br />
			<i><b>Stroke Limiter</b></i></span>
			</p>
</td>
</tr>
<tr>
<td width="40%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td width="60%">&nbsp;</td>
</tr>
<tr>
<td width="40%"><b><span style="font-size: 10pt; font-family: Arial">1114</span></b></p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial"><br />
			</span>
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial">With optical position indicator<br />
			and emergency manual operation facility<br />
			<i><b>Stroke Limiter</b></i></span>
			</p>
</td>
<td valign="top" width="60%"><b><span style="font-size: 10pt; font-family: Arial">1151/1153/1154</span></b></p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial"><br />
			</span>
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial">With optical position indicator<br />
			Control function 1<br />
			<i><b>Stroke Limiter</b></i></span>
			</p>
</td>
</tr>
<tr>
<td width="40%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td width="60%">&nbsp;</td>
</tr>
<tr>
<td valign="top" width="40%"><b><span style="font-size: 10pt; font-family: Arial">1161/1165</span></b></p>
<p align="left">
			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial">With optical position indicator<br />
			Control function 2<br />
			<i><b>Stroke Limiter</b></i></span>
			</p>
</td>
<td valign="top" width="60%"><b><span style="font-size: 10pt; font-family: Arial">1301</span></b></p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial"><br />
			</span>
			</p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial">For the type 1104 Stroke limiter<br />
			<i><b>Transparent cap (sight glass)</b></i></span>
			</p>
</td>
</tr>
</tbody>
</table>
<p></p>
<table border="0" cellpadding="0" cellspacing="0" width="76%">
<tbody>
<tr>
<td valign="top" width="40%"><b><span style="font-size: 10pt; font-family: Arial">1300</p>
<p>			</span></b></td>
<td valign="top" width="60%"><b><span style="font-size: 10pt; font-family: Arial"></span></b>
			</td>
</tr>
</tbody>
</table>
<p>
<a href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/Optical%20Indicators%20stroke%20limiters.pdf" target="_blank" title="All Products Overview PDF" class="jce_file">All Products Overview PDF</a><br />
<span id="more-64"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/stroke-limiters/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Position Indicators</title>
		<link>http://gemuvalvesonline.com/position-indicators/</link>
		<comments>http://gemuvalvesonline.com/position-indicators/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:44:34 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Accessories]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=63</guid>
		<description><![CDATA[1201 For valve types: 312, 314, 512, 554, 600, 620, 667, 687, 690, 695 &#160; &#160; With micro switches Electrical Position Indicator 1205 For valve types: 312, 314, 512, 514, 554, 600, 620, 667, 687, 690, 695 Explosion-proof design Electrical Position Indicator &#160; &#160; &#160; 1211 For valve types: 312, 314, 512, 514, 554, 600,620, [&#8230;]]]></description>
				<content:encoded><![CDATA[<table border="0" height="1457" width="91%">
<tbody>
<tr>
<td height="246" valign="top" width="47%"><span style="font-size: 10pt; font-family: Arial"><span style="color: #ff0000"><b>1201</b></span></p>
<p>			For valve types:<br />
			312, 314, 512, 554, 600, 620, 667, 687, 690, 695</p>
<p>			</span></p>
<p>
			&nbsp;
			</p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial">With micro switches<br />
			<i><b>Electrical Position Indicator</b></i></span>
			</p>
</td>
<td height="246" valign="top" width="53%">
<p align="left">
			<span style="font-size: 10pt; font-family: Arial"><span style="color: #ff0000"><b>1205</b></span></p>
<p>			For valve types:<br />
			312, 314, 512, 514, 554, 600, 620, 667, 687, 690, 695<br />
			</span>
			</p>
<p align="left">
			<span style="font-size: 10pt; font-family: Arial"></p>
<p>			Explosion-proof design<br />
			<i><b>Electrical Position Indicator</b></i></span>
			</p>
</td>
</tr>
<tr>
<td height="59" width="47%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td height="59" width="53%">&nbsp;</td>
</tr>
<tr>
<td height="274" valign="top" width="47%"><span style="font-family: Arial"><a name="1211" title="1211"></a><b><span style="font-size: 10pt; color: #ff0000">1211</span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			</span><span style="font-size: 10pt; font-family: Arial">For valve types:<br />
			312, 314, 512, 514, 554, 600,620, 667, 687, 690,695 </span><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			</span></span></p>
<p>
			&nbsp;
			</p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial">With proximity switches&nbsp; according to NAMUR<br />
			<i><b>Electrical Position Indicator</b></i></span>
			</p>
</td>
<td height="274" valign="top" width="53%"><span style="font-family: Arial"><a name="1214" title="1214"></a><b><span style="font-size: 10pt; color: #ff0000">1214</span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			</span><span style="font-size: 10pt; font-family: Arial">For valve types:<br />
			312, 314, 512, 514, 554, 600, 620, 667, 687, 690, 695</span></span></p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial"><br />
			With proximity switches and<br />
			integral amplifier<br />
			<i><b>Electrical Position Indicator</b></i></span>
			</p>
</td>
</tr>
<tr>
<td height="59" width="47%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td height="59" width="53%">&nbsp;</td>
</tr>
<tr>
<td height="256" valign="top" width="47%"><span style="font-size: 10pt; font-family: Arial"><span style="color: #ff0000"><b>1230</b></span></p>
<p>			&nbsp;For valve types:<br />
			312, 314, 512, 514, 554, 600, 603, 604, 605, 610, 615, 625, 687, 690, 695</span></p>
<p>
			<span style="font-size: 10pt; font-family: Arial"></p>
<p>			With micro-switches<br />
			<i><b>Electrical Position Indicator</b></i></span>
			</p>
</td>
<td height="256" valign="top" width="53%"><span style="font-family: Arial"><b><span style="font-size: 10pt; color: #ff0000"><a name="1231/1232" title="1231/1232"></a>1231/1232</span></b><span style="font-size: 10pt"></p>
<p>			&nbsp;For valve types:<br />
			312, 314, 512, 514, 554, 600, <br />
			603, 604, 605, 610, 615, 625, <br />
			687, 690, 695</p>
<p>			Type 1231<br />
			. . . . with proximity switches<br />
			Two wires according to NAMUR</p>
<p>			Type 1232<br />
			. . . . with proximity switches<br />
			<i><b>Electrical Position Indicator</b></i></span></span></td>
</tr>
<tr>
<td height="59" width="47%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td height="59" width="53%">&nbsp;</td>
</tr>
<tr>
<td height="189" valign="top" width="47%"><span style="font-size: 10pt; font-family: Arial"><span style="color: #ff0000"><b>1215</b></span></p>
<p>			For valve types:<br />
			312, 314, 512, 554, 600, 603, 604, 605, 610, 615, 625, 667, 671, 687, 690</span></p>
<p>
			<span style="font-size: 10pt; font-family: Arial"></p>
<p>			With micro switches<br />
			<i><b>Electrical Position Indicator</b></i></span>
			</p>
</td>
<td height="189" valign="top" width="53%"><span style="font-family: Arial"><b><span style="font-size: 10pt; color: #ff0000">1225</span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT">&nbsp;<span style="font-family: Arial">For valve types:<br />
			410, 411, 413, 415, 417, 418, 423, 428</span></span></p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial"><br />
			With micro switches<br />
			<i><b>Electrical Position Indicator</b></i></span>
			</p>
</td>
</tr>
<tr>
<td height="59" width="47%">&nbsp;</p>
<p>
			&nbsp;
			</p>
</td>
<td height="59" width="53%">&nbsp;</td>
</tr>
<tr>
<td height="220" valign="top" width="47%"><span style="font-family: Arial"><b><span style="font-size: 10pt"><span style="color: #ff0000">1310</span></span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			</span></span><span style="font-size: 10pt; font-family: Arial">For valve types:<br />
			687, 690, 695, 415</p>
<p>			control function 1</span></p>
<p>
			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt"><span style="font-family: Arial"><b><i>Electrical Position Indicator</i><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
			</span></b>for proximity switch adaptation<br />
			( M 18 x 1)</span></span>
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial"></p>
<p>			</span>
			</p>
</td>
<td height="220" valign="top" width="53%"></p>
<p>
			<i><b><span style="font-size: 10pt; font-family: Arial">Optical Position Indicator</span></b></i>
			</p>
</td>
</tr>
</tbody>
</table>
<p>
&nbsp;
</p>
<table style="width: 522px; height: 145px" border="0" height="145" width="522">
<tbody>
<tr>
<td height="220" valign="top" width="47%"><span style="font-family: Arial"><b><span style="font-size: 10pt"><span style="color: #ff0000">1234</span></span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"></p>
<p>			</span></span></p>
<p>			&nbsp;
			</p>
<p>
			<span style="font-size: 10pt"><span style="font-family: Arial"><b><i>Electrical Position Indicator</i><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
			</span></b></span></span>
			</p>
<p>
			<span style="font-size: 10pt; font-family: Arial"></p>
<p>			</span>
			</p>
</td>
<td height="220" valign="top" width="53%"><span style="font-size: 10pt; font-family: Arial"><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><b>1235</b></p>
<p>			</span></p>
<p>
			<b></p>
<p>			</b>&nbsp;
			</p>
<p>
			<span style="font-size: 10pt"><span style="font-family: Arial"><i><b>Electrical Position Indicator</b></i></span></span>
			</p>
<p>			</span></td>
</tr>
</tbody>
</table>
<p><a href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/Electrical%20Position%20Indicators.pdf" target="_blank" title="All Products Overview PDF" class="jce_file">All Products Overview PDF</a><br />
<span id="more-63"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/position-indicators/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Digital Display Unit</title>
		<link>http://gemuvalvesonline.com/digital-display-unit/</link>
		<comments>http://gemuvalvesonline.com/digital-display-unit/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:41:45 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=62</guid>
		<description><![CDATA[A panel mountable unit for display of standard electrical signals used in measurement and control engineering applications. The units are available as either models ZA (3&#189;-digit) or ZB, ZP (4&#189;-digit) and comply with standard mounting dimensions 96 x 48 mm.&#160; They are both fitted with 14mm high red LED displays and are accurate to 0.1% [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; font-family: Arial">A panel mountable unit for display of standard electrical signals used in measurement and control engineering applications.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The units are available as either models ZA (3&frac12;-digit) or ZB, ZP (4&frac12;-digit) and comply with standard mounting dimensions 96 x 48 mm.&nbsp; They are both fitted with 14mm high red LED displays and are accurate to 0.1% of the effective range limit.&nbsp; The display value is easily set using the two-point method, by applying respective measurement signals and setting the required display variable. The use of various supply voltages and optional&nbsp; sensor supply contribute to the universal applicability of the display units.&nbsp; While in the ZA and ZB models, the setting potentiometer is located safely behind the protective front panel away from unauthorized access, the model ZP can be digitally programmed at the front using a disconnectable keypad and also equipped with up to a maximum of 4 relay contacts and an analogue output or digital serial interface.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The digital display units of the 1275 series are used in mechanical installations, as evaluating units for pressure gauges and temperature monitoring devices, as indicators for flow meters or to display electrical signals of the kind supplied by all GEM&Uuml; sensors and pick-ups.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">They are used as units for measured value acquisition for computers.&nbsp; The a precision display in any required unit of measurement, simple limiting value adjustment and range of useful options, these digital indicator models provide an invaluable aid to operating staff.</span>
</p>
<p>
<b><span style="text-transform: uppercase"><span style="font-size: 10pt; font-family: Arial; color: #ff0000">Type 1275/000/ZA and ZB (Basic configuration)</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<hr align="center" />
<p>
<b><span style="font-family: Arial"><span style="text-transform: uppercase"><span style="font-size: 10pt; color: #ff0000">Type 1275/000/ZP (Multi-function display</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT; color: #ff0000">)</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p><span id="more-62"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/digital-display-unit/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Voltage Transformer</title>
		<link>http://gemuvalvesonline.com/voltage-transformer/</link>
		<comments>http://gemuvalvesonline.com/voltage-transformer/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:40:56 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=61</guid>
		<description><![CDATA[The E-module 1572 provides a power supply for d.c. actuators with integral motor protection from a specified a.c. voltage. The E-module converts an a.c. voltage to a 20 V pulsed unidirectional voltage. An external switch can be used to reverse the voltage polarity and hence the direction of rotation of d.c. actuators. The respective end [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; font-family: Arial">The E-module <b>1572</b> provides a power supply for d.c. actuators with integral motor protection from a specified a.c. voltage.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The E-module converts an a.c. voltage to a 20 V pulsed unidirectional voltage.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">An external switch can be used to reverse the voltage polarity and hence the direction of rotation of d.c. actuators.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The respective end positions of the actuator, &quot;open&quot; or &quot;closed&quot; are indicated by LED&#8217;s (green LED or red LED).&nbsp; The power supply is indicated by a yellow LED.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">In parallel with the programmable outputs, an additional unsmoothed 20 V d.c. terminal is available (e.g. the pilot conductor for E-module 1570).</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The voltage transformer is built into a universally compatible housing which is designed for panel mounting or direct attachment to the respective GEM&Uuml; actuator.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The output voltage is protected by a 1.6 A fuse.</span>
</p>
<p>
<span style="font-family: Arial"><b><span style="font-size: 10pt">Voltage: </span></b><span style="font-size: 10pt"><b></b>24 V d.c.<br />
<b>Permissible voltage variation:</b> &plusmn; 10%<br />
<b>Power consumption:</b> 2W<br />
<b>N.B.:</b> A charging period of at least 16 h is required before putting the unit into service</span></span>
</p>
<p>
<span style="font-family: Arial"><b><span style="font-size: 10pt">Max. input/output loading:&nbsp;</span></b><span style="font-size: 10pt"><b>&nbsp; </b>24V d.c., 4A</span><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
<b>Output voltage:</b>&nbsp;</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT"> <span style="font-family: Arial">UB16.5 V d.c.<br />
<b>Capacity:</b> 110 mA/h<br />
<b>Internal fuse:</b> M 4/250 V<br />
<b>Weight:</b> 410 g&nbsp; (.90 lbs.)<br />
<b>Cable gland:</b> PG 13.5 </span></span>
</p>
<p><span id="more-61"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/voltage-transformer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Temperature Transducer</title>
		<link>http://gemuvalvesonline.com/temperature-transducer/</link>
		<comments>http://gemuvalvesonline.com/temperature-transducer/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:40:11 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=60</guid>
		<description><![CDATA[Temperature transducer in an all-plastic housing with Pt 100 resistance sensor for temperature measurements for 0-100&#176; C (0-212&#176;F). The temperature transducer type 3220 converts to the physical variable temperature proportionally into an electrical signal.&#160; It is available in the form of a two-wire transducer (4-20 mA) and as a temperature measuring instrument with an optional [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; font-family: Arial">Temperature transducer in an all-plastic housing with Pt 100 resistance sensor for temperature measurements for 0-100&deg; C (0-212&deg;F).</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The temperature transducer type 3220 converts to the physical variable temperature proportionally into an electrical signal.&nbsp; It is available in the form of a two-wire transducer (4-20 mA) and as a temperature measuring instrument with an optional power (0/4 &#8211; 20 mA) or relay output (MIN and MAX switching points).</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The process connection is configured as standard with male threads, to DIN 3852 in sizes G 1/2 A and G 3/4A.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">Electrical connections are effected using an electrical plug in compliance with DIN 43650, PG 11.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The transducer can be mounted in any position.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">After screwing in the connecting element, the upper part of the housing can be turned up to &plusmn;180&deg; to the required position by releasing the fastening screws.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">Components coming into contact with the medium are made of PVDF or stainless steel, the housing is made of ABS and the seal of FPM.&nbsp; Other seal materials are available on request.</span>
</p>
<p align="left">
<b><span style="text-transform: uppercase"><span style="font-size: 10pt; font-family: Arial; color: #ff0000">Type 3220</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p><span id="more-60"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/temperature-transducer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
