<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gemu Valves &#187; Controllers / Positioners</title>
	<atom:link href="http://gemuvalvesonline.com/category/home/controllers-positioners/feed/" rel="self" type="application/rss+xml" />
	<link>http://gemuvalvesonline.com</link>
	<description></description>
	<lastBuildDate>Sat, 13 Sep 2014 18:12:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.42</generator>
	<item>
		<title>Positioners</title>
		<link>http://gemuvalvesonline.com/positioners/</link>
		<comments>http://gemuvalvesonline.com/positioners/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:47:00 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=66</guid>
		<description><![CDATA[1434 &#160; &#160;1434 Positioner PDF &#160; 1435 1435 Positioner PDF 1436 1436 Positioner PDF 1434-1436 Overview PDF]]></description>
				<content:encoded><![CDATA[<table border="0" width="100%">
<tbody>
<tr>
<td width="50%"><strong><span style="font-size: 10pt; color: #ff0000; font-family: Arial"></p>
<p align="left">
			<strong><span style="font-size: 10pt; color: #ff0000; font-family: Arial">1434</span></strong>
			</p>
<p align="left">
			&nbsp;
			</p>
<p align="left">
			<br />
			&nbsp;<a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1434_positioner.pdf" title="1434 Positioner PDF" class="jce_file">1434 Positioner PDF</a>
			</p>
<p>			</span></strong></p>
<hr align="center" />
			</td>
</tr>
<tr>
<td width="50%">
<p>
			&nbsp;
			</p>
</td>
</tr>
<tr>
<td width="50%" vAlign="top">
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"><strong>1435</strong></span></span>
			</p>
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
<p>			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"><a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1435%20Positioner.pdf" title="1435 Positioner PDF" class="jce_file"><strong>1435 Positioner PDF</strong></a></p>
<hr align="center" />
<p>
			<span style="font-family: Verdana"></span>
			</p>
<p>			</span></span></td>
</tr>
</tbody>
</table>
<table border="0" width="574" style="width: 574px; height: 200px">
<tbody>
<tr>
<td width="50%"><span style="font-size: 10pt; color: #ff0000; font-family: Arial"></p>
<p align="left">
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><strong>1436</strong></span>
			</p>
<p>			</span><a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1436_positioner.pdf" title="1436 Positioner PDF" class="jce_file"><strong>1436 Positioner PDF</strong></a></p>
<hr align="center" />
			</td>
</tr>
<tr>
<td width="50%">
<p>
			<a target="_blank" href="http://gemuvalves.server263.com/wp-content/uploads/images/stories/1434-1436_Overview.pdf" title="1434-1436 Overview PDF" class="jce_file"><strong>1434-1436 Overview PDF</strong></a>
			</p>
</td>
</tr>
<tr>
<td width="50%" vAlign="top">
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
<p>
			<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><span style="font-family: Arial Rounded MT Bold"></span></span>
			</p>
</td>
</tr>
</tbody>
</table>
<p><span id="more-66"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/positioners/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Digital Display Unit</title>
		<link>http://gemuvalvesonline.com/digital-display-unit/</link>
		<comments>http://gemuvalvesonline.com/digital-display-unit/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:41:45 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=62</guid>
		<description><![CDATA[A panel mountable unit for display of standard electrical signals used in measurement and control engineering applications. The units are available as either models ZA (3&#189;-digit) or ZB, ZP (4&#189;-digit) and comply with standard mounting dimensions 96 x 48 mm.&#160; They are both fitted with 14mm high red LED displays and are accurate to 0.1% [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; font-family: Arial">A panel mountable unit for display of standard electrical signals used in measurement and control engineering applications.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The units are available as either models ZA (3&frac12;-digit) or ZB, ZP (4&frac12;-digit) and comply with standard mounting dimensions 96 x 48 mm.&nbsp; They are both fitted with 14mm high red LED displays and are accurate to 0.1% of the effective range limit.&nbsp; The display value is easily set using the two-point method, by applying respective measurement signals and setting the required display variable. The use of various supply voltages and optional&nbsp; sensor supply contribute to the universal applicability of the display units.&nbsp; While in the ZA and ZB models, the setting potentiometer is located safely behind the protective front panel away from unauthorized access, the model ZP can be digitally programmed at the front using a disconnectable keypad and also equipped with up to a maximum of 4 relay contacts and an analogue output or digital serial interface.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The digital display units of the 1275 series are used in mechanical installations, as evaluating units for pressure gauges and temperature monitoring devices, as indicators for flow meters or to display electrical signals of the kind supplied by all GEM&Uuml; sensors and pick-ups.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">They are used as units for measured value acquisition for computers.&nbsp; The a precision display in any required unit of measurement, simple limiting value adjustment and range of useful options, these digital indicator models provide an invaluable aid to operating staff.</span>
</p>
<p>
<b><span style="text-transform: uppercase"><span style="font-size: 10pt; font-family: Arial; color: #ff0000">Type 1275/000/ZA and ZB (Basic configuration)</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<hr align="center" />
<p>
<b><span style="font-family: Arial"><span style="text-transform: uppercase"><span style="font-size: 10pt; color: #ff0000">Type 1275/000/ZP (Multi-function display</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT; color: #ff0000">)</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p><span id="more-62"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/digital-display-unit/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Voltage Transformer</title>
		<link>http://gemuvalvesonline.com/voltage-transformer/</link>
		<comments>http://gemuvalvesonline.com/voltage-transformer/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:40:56 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=61</guid>
		<description><![CDATA[The E-module 1572 provides a power supply for d.c. actuators with integral motor protection from a specified a.c. voltage. The E-module converts an a.c. voltage to a 20 V pulsed unidirectional voltage. An external switch can be used to reverse the voltage polarity and hence the direction of rotation of d.c. actuators. The respective end [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; font-family: Arial">The E-module <b>1572</b> provides a power supply for d.c. actuators with integral motor protection from a specified a.c. voltage.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The E-module converts an a.c. voltage to a 20 V pulsed unidirectional voltage.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">An external switch can be used to reverse the voltage polarity and hence the direction of rotation of d.c. actuators.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The respective end positions of the actuator, &quot;open&quot; or &quot;closed&quot; are indicated by LED&#8217;s (green LED or red LED).&nbsp; The power supply is indicated by a yellow LED.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">In parallel with the programmable outputs, an additional unsmoothed 20 V d.c. terminal is available (e.g. the pilot conductor for E-module 1570).</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The voltage transformer is built into a universally compatible housing which is designed for panel mounting or direct attachment to the respective GEM&Uuml; actuator.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The output voltage is protected by a 1.6 A fuse.</span>
</p>
<p>
<span style="font-family: Arial"><b><span style="font-size: 10pt">Voltage: </span></b><span style="font-size: 10pt"><b></b>24 V d.c.<br />
<b>Permissible voltage variation:</b> &plusmn; 10%<br />
<b>Power consumption:</b> 2W<br />
<b>N.B.:</b> A charging period of at least 16 h is required before putting the unit into service</span></span>
</p>
<p>
<span style="font-family: Arial"><b><span style="font-size: 10pt">Max. input/output loading:&nbsp;</span></b><span style="font-size: 10pt"><b>&nbsp; </b>24V d.c., 4A</span><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
<b>Output voltage:</b>&nbsp;</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT"> <span style="font-family: Arial">UB16.5 V d.c.<br />
<b>Capacity:</b> 110 mA/h<br />
<b>Internal fuse:</b> M 4/250 V<br />
<b>Weight:</b> 410 g&nbsp; (.90 lbs.)<br />
<b>Cable gland:</b> PG 13.5 </span></span>
</p>
<p><span id="more-61"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/voltage-transformer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Temperature Transducer</title>
		<link>http://gemuvalvesonline.com/temperature-transducer/</link>
		<comments>http://gemuvalvesonline.com/temperature-transducer/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:40:11 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=60</guid>
		<description><![CDATA[Temperature transducer in an all-plastic housing with Pt 100 resistance sensor for temperature measurements for 0-100&#176; C (0-212&#176;F). The temperature transducer type 3220 converts to the physical variable temperature proportionally into an electrical signal.&#160; It is available in the form of a two-wire transducer (4-20 mA) and as a temperature measuring instrument with an optional [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; font-family: Arial">Temperature transducer in an all-plastic housing with Pt 100 resistance sensor for temperature measurements for 0-100&deg; C (0-212&deg;F).</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The temperature transducer type 3220 converts to the physical variable temperature proportionally into an electrical signal.&nbsp; It is available in the form of a two-wire transducer (4-20 mA) and as a temperature measuring instrument with an optional power (0/4 &#8211; 20 mA) or relay output (MIN and MAX switching points).</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The process connection is configured as standard with male threads, to DIN 3852 in sizes G 1/2 A and G 3/4A.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">Electrical connections are effected using an electrical plug in compliance with DIN 43650, PG 11.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The transducer can be mounted in any position.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">After screwing in the connecting element, the upper part of the housing can be turned up to &plusmn;180&deg; to the required position by releasing the fastening screws.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">Components coming into contact with the medium are made of PVDF or stainless steel, the housing is made of ABS and the seal of FPM.&nbsp; Other seal materials are available on request.</span>
</p>
<p align="left">
<b><span style="text-transform: uppercase"><span style="font-size: 10pt; font-family: Arial; color: #ff0000">Type 3220</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p><span id="more-60"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/temperature-transducer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Pressure Transducer</title>
		<link>http://gemuvalvesonline.com/pressure-transducer/</link>
		<comments>http://gemuvalvesonline.com/pressure-transducer/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:38:55 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=59</guid>
		<description><![CDATA[Pressure transducer in an all-plastic housing for relative pressure measurements for 0-10 bar (0-150 psi). The pressure transducer type 3120 converts the physical variable pressure proportionally into an electrical signal.&#160; It is available in the form of a two-wire transducer (4-20mA) and as a pressure measuring instrument with an optional power (0/4-20mA) or relay output [&#8230;]]]></description>
				<content:encoded><![CDATA[<p align="left">
<span style="font-size: 10pt; font-family: Arial">Pressure transducer in an all-plastic housing for relative pressure measurements for 0-10 bar (0-150 psi).</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">The pressure transducer type 3120 converts the physical variable pressure proportionally into an electrical signal.&nbsp; It is available in the form of a two-wire transducer (4-20mA) and as a pressure measuring instrument with an optional power (0/4-20mA) or relay output (MIN and MAX switching points).&nbsp; The pick-up is temperature compensated.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">The element connecting the transducer to the pipeline is configured as standard with male thread, optionally to DIN 3852 or DIN 16288, in sizes G 1/4 A, G 1/2 A and G 3/4 A.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">Electrical connections are effected using an electrical plug in compliance with DIN 43650, PG 11.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">The transducer can be mounted in any position.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">After screwing in the connecting element, the upper part of the housing can be turned up to &plusmn;180&deg; to the required position by releasing the fastening screws.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">Components coming into contact with the medium are made of PVDF or stainless steel, the housing is made of ABS and the seal of FPM.&nbsp; Other seal materials are available on request.</span>
</p>
<p align="left">
<b><span style="text-transform: uppercase"><span style="font-size: 10pt; font-family: Arial; color: #ff0000">Type 3120</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p><span id="more-59"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/pressure-transducer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Flow Transmitter</title>
		<link>http://gemuvalvesonline.com/flow-transmitter/</link>
		<comments>http://gemuvalvesonline.com/flow-transmitter/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:37:53 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=58</guid>
		<description><![CDATA[Flow transmitter featuring non-metallic internal components for the measurement and transmission of volume flow for inert and corrosive liquids. The flow transmitter picks up the entire volumetric flow and is therefore insensitive even in the event of an uneven flow profile within a cross-section. There is no need to adhere to a special mounting position [&#8230;]]]></description>
				<content:encoded><![CDATA[<p align="left">
<span style="font-size: 10pt; font-family: Arial">Flow transmitter featuring non-metallic internal components for the measurement and transmission of volume flow for inert and corrosive liquids.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">The flow transmitter picks up the entire volumetric flow and is therefore insensitive even in the event of an uneven flow profile within a cross-section.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">There is no need to adhere to a special mounting position or other installation parameters.&nbsp; A mounting distance of 5 times DN on the inlet and outlet side is sufficient.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">Components coming into contact with the medium are made of PVDF, with the shaft and bearings in a ceramic material.&nbsp; The housing is made of PVC.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">The electronic evaluation system including the sensor is mechanically attached to the turbine housing by means of stainless steel screws.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">Rotation of the turbine is picked off inductively, with the speed of the rotor proportional to flow.</span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial">The turbine can be quickly, reliably and simply mounted and removed by means of a union with DIN bushes.</span>
</p>
<p align="left">
<b><span style="text-transform: uppercase"><span style="font-size: 10pt; font-family: Arial; color: #ff0000">Type 3020</span></span></b>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p><span id="more-58"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/flow-transmitter/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Emergency Power Supply Unit</title>
		<link>http://gemuvalvesonline.com/emergency-power-supply-unit/</link>
		<comments>http://gemuvalvesonline.com/emergency-power-supply-unit/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:37:09 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=57</guid>
		<description><![CDATA[The 1570 E-Module provides an emergency power supply for direct current actuators. In the case of loss of mains supply, the E-Module supplies power to the connected d.c. actuator by means of integral rechargeable battery. In normal operation the battery is held on trickle charge from the main voltage. The required final position of the [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; font-family: Arial">The 1570 E-Module provides an emergency power supply for direct current actuators.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">In the case of loss of mains supply, the E-Module supplies power to the connected d.c. actuator by means of integral rechargeable battery.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">In normal operation the battery is held on trickle charge from the main voltage.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The required final position of the actuated unit on loss of mains power can be programmed by means of a selector switch.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The setting of the switch can be sealed against unauthorized interference by a transparent cover over the switch lever.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">LED indicators built into the unit show whether the mains supply (yellow LED) or the emergency supply (red LED) is in use.</span>
</p>
<p>
<span style="font-family: Arial"><b><span style="text-transform: uppercase"><span style="font-size: 10pt; color: #ff0000">Type 1570</span></span><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
</span></b><span style="font-size: 10pt; font-family: Arial">Emergency power supply unit built into a universal compatible plastic housing, designed for incorporation in a control panel or direct mounting onto the corresponding GEM&Uuml; actuator.</span></span>
</p>
<p align="left">
<span style="font-family: Arial"><b><span style="font-size: 10pt">Example:</span></b><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
</span><span style="font-size: 10pt; font-family: Arial">Type 423 + 1570</span></span>
</p>
<p align="left">
<span style="font-size: 10pt; font-family: Arial"><br />
</span>
</p>
<p>
<span style="font-family: Arial"><b><span style="font-size: 10pt">Voltage:</span></b> <span style="font-size: 10pt; font-family: AvantGarde Bk BT">110, 220 V/50-60Hz<br />
<b>Permissible voltage deviation:</b> &plusmn; 10%<br />
<b>Power consumption</b>: 35 VA</span></span>
</p>
<p>
<span style="font-family: Arial"><b><span style="font-size: 10pt">Output voltage:</span></b> <span style="font-size: 10pt; font-family: AvantGarde Bk BT">20 V d.c. unsmoothed<br />
<b>Output current:</b> 1.4 A<br />
<b>Input fusing:</b> M 1.6/250 V<br />
<b>Weight:</b> 970 g<br />
<b>Cable gland:</b> PG 13.5</span></span>
</p>
<p><span id="more-57"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/emergency-power-supply-unit/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Isolating Switch Amplifiers</title>
		<link>http://gemuvalvesonline.com/isolating-switch-amplifiers/</link>
		<comments>http://gemuvalvesonline.com/isolating-switch-amplifiers/#comments</comments>
		<pubDate>Wed, 03 Dec 2008 10:28:33 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Controllers / Positioners]]></category>
		<category><![CDATA[Home]]></category>

		<guid isPermaLink="false">http://127.0.0.1/wordpress44/?p=54</guid>
		<description><![CDATA[&#160;&#160;&#160; The type 1520 and 1521 isolating switch amplifiers are suitable for the following applications: Overload protection for light duty switches Mains voltage isolating component for main circuits and also for control circuits Switch position indicators When the isolating switch amplifier is used, reed switches and other light duty switches will be protected against overloads [&#8230;]]]></description>
				<content:encoded><![CDATA[<p>
<span style="font-size: 10pt; color: #ff0000; font-family: Arial"><img width="105" src="http://www.gemu.com/images/regula1.gif" alt="wpe6.jpg (1309 bytes)" height="19" />&nbsp;<strong>&nbsp;<span style="text-transform: uppercase">&nbsp; </span></strong></span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">The type 1520 and 1521 isolating switch amplifiers are suitable for the following applications:</span>
</p>
<ul>
<li><span style="font-size: 10pt; font-family: Arial">Overload protection for light duty switches</span> </li>
<li><span style="font-size: 10pt; font-family: Arial">Mains voltage isolating component for main circuits and also for control circuits</span> </li>
<li><span style="font-size: 10pt; font-family: Arial">Switch position indicators</span> </li>
</ul>
<p>
<span style="font-size: 10pt; font-family: Arial">When the isolating switch amplifier is used, reed switches and other light duty switches will be protected against overloads since they will then not have to deal with currents above their rating.&nbsp; There is a danger of overload, with sparking and high currents caused by self-inductance voltages when breaking inductive loads such as power relays, solenoid valves and motors.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">Both the control circuits are galvanically separated from the mains so that, if an earth fault occurs, no high voltages will appear on the installation.</span>
</p>
<p>
<span style="font-size: 10pt; font-family: Arial">These E-Modules are used in conjunction with GEM&Uuml; type series 1251-1257 limit switches or GEM&Uuml; type series 1211, 1214 and 1232 position indicators.</span>
</p>
<p>
<strong><span style="text-transform: uppercase"><span style="font-size: 10pt; color: #ff0000; font-family: Arial">Type 1520</span></span></strong>
</p>
<p>
<span style="font-family: Arial"><span style="font-size: 10pt"><strong><img align="left" width="116" src="http://www.gemu.com/images/1520.gif" alt="1520.jpg (10018 bytes)" height="173" /></strong><b>Type 1520/000/Z 02</b><br />
Desk or panel mounting, 2 relays<br />
1 x Min. (red LED); 1 x Max. (red LED); 1 x mains (yellow LED)<br />
</span></span>
</p>
<p>
&nbsp;
</p>
<p>
<span style="font-size: 10pt; font-family: Arial"><b>Type 1520/000/Z 04</b><br />
Desk or panel mounting, 4 relays<br />
2 x Min. (red LED); 2 x Max. (red LED); 1 x mains (yellow LED)</span>
</p>
<p>
&nbsp;
</p>
<hr align="center" />
<p>
<strong><span style="text-transform: uppercase"><span style="font-size: 10pt; color: #ff0000; font-family: Arial">Type 1521</span></span></strong>
</p>
<p>
<span style="font-family: Arial"><strong><span style="font-size: 10pt"><img align="left" width="136" src="http://www.gemu.com/images/1521.gif" alt="1521.jpg (7921 bytes)" height="240" />Type 1521/000/Z 02</span></strong><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
</span><span style="font-size: 10pt">Eurocard with 31 pole terminal block to DIN 41617 for 19&quot; or 24&quot; rack; 2 relays<br />
1 x Min. (red LED); 1 x Max. (red LED); 1 x mains (yellow LED)</span></span>
</p>
<p>
&nbsp;
</p>
<p>
&nbsp;
</p>
<p>
<span style="font-family: Arial"><strong><span style="font-size: 10pt">Type 1521/000/Z 04</span></strong><span style="font-size: 10pt; font-family: AvantGarde Bk BT"><br />
</span><span style="font-size: 10pt; font-family: Arial">Eurocard with 31 pole terminal block to DIN 41617 for 19&quot; or 24&quot; rack; 4 relays<br />
2 x Min. (red LED); 2 x Max. (red LED); 1 x mains (yellow LED)</span></span>
</p>
<p><span id="more-54"></span><br /></p>
]]></content:encoded>
			<wfw:commentRss>http://gemuvalvesonline.com/isolating-switch-amplifiers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
